Logger Script Model 2400-C - Keithley ::NUBICOM::
top
New Products

Model 2400-C 범용 소스미터

Model 2400-CCart

Keithley's SourceMeter family is designed specifically for test applications that demand tightly coupled sourcing and measurement. All SourceMeter models provide precision voltage and current sourcing as well as measurement capabilities. Each source-measure instrument is both a highly stable DC power source and a true instrument-grade 5-1/2 digit multimeter. The power source characteristics include low noise, precision, and readback. The multimeter capabilities include high repeatability and low noise. The result is a compact, single-channel, DC parametric tester. In operation, these instruments can act as a voltage source, a current source, a voltage meter, a current meter, and an ohmmeter. Manufacturers of components and modules for the communications, semiconductor, computer, automotive, and medical industries will find the SourceMeter instruments invaluable for a wide range of characterization and production test applications.

The Model 2400-C SourceMeter® is a 20W instrument that allows sourcing and measuring voltage from ±5µV (sourcing) and ±1µV (measuring) to ±200V DC and current from ±10pA to ±1A. It's well-suited for testing a wide range of devices, including diodes, resistors, resistor networks, active circuit protection devices, and portable battery-powered devices and components. It's also useful for systems power sourcing and IDDQ testing applications. The Contact Check function makes it simple to maximize test integrity by verifying test connections easily in just 350µs before an automated test sequence begins. This eliminates measurement errors and false product failures associated with contact fatigue, breakage, contamination, loose or broken connection, relay failures, etc.
Model 2400-C의 주요기능
  • Completes the contact check verification and notification process in just 350µs to maintain high speed production throughput
  • Contact Check enabled on the instrument's front panel or remotely via the GPIB
  • Built-in "Source Memory" programmable sequencer stores up to 100 different tests for high production throughput
  • Rugged design with 75,000-hour MTBF provides reliability in non-stop production environments.
  • Built-in comparator simplifies pass/fail testing
  • Digital I/O for fast binning or connection to component handlers
  • 0.012% basic accuracy with 5-1/2-digit resolution for precise measurements
어플리케이션 분야
  • Devices:
    • Discrete semiconductor devices
    • Passive devices
    • Transient suppression devices
    • ICs, RF ICs, MMICs
    • Laser diodes, Laser diode modules, LEDs, Photodetectors
    • Circuit protection devices: TVS, MOV, Fuses, etc.
    • Airbags
    • Connectors, switches, relays
    • High brightness LEDs (DC and pulse)
  • Tests:
    • Leakage
    • Low voltage/resistances
    • LIV
    • IDDQ
    • I-V characterization
    • Isolation and trace resistance
    • Temperature coefficient
    • Forward voltage, reverse breakdown, leakage current
    • DC parametric test
    • DC power source
    • HIPOT
    • Photovoltaic cell efficiency (source and sink)
    • Dielectric withstanding
관련 자료
데이터 시트 SourceMeter Instruments for Optoelectronic I-V Testing
Series 2400 SourceMeter Line
Technical Information - Source Measurement Unit (SMU) Instruments
어플리케이션 노트 #1818 Configuring a Resistor Network Production Test System with the Model 2400
#803 Varistor Verification with the 2400 Digital SourceMeter
#804 IDDQ Testing and Standby Current Testing with the Series 2400 SourceMeter
#805 Configuring a Discrete Resistor Verification Test System
#807 Battery Discharge/Charge Cycling Using Keithley Series 2400 SourceMeter
Using Two Model 2400 SourceMeter Instruments to Source up to 2 Amps
#1805 Diode Production Testing with the Series 2400 SourceMeter
#2202 Production Testing of GMR Heads with the Model 2400 and Model 7001
#1953 Measuring Photovoltaic Cell I-V Characteristics with the Model 2420
#2273 VCSEL Testing with the Model 2400 SourceMeter Instrument
#2402 DC Production Testing of OLED Displays
#2124 Production Testing of High Current Varistors with the 2430C 1kW Pulse SourceMeter
Word 6.0 File Discussing the Issues of Ohms Accuracy with the 2400 Series
Technical Note for SourceMeter Buffers and How to Get Up to 5000 Data Points Using the Two Buffers
2400 Series Timestamping Technical Note
Automatic Resistance Measurements on High Temperature Superconductors
Determining output resistance for the 2400 Series SourceMeter
Can I generate current (or voltage) pulses with model 2400 or other non-pulse mode SourceMeter?
Device Characterization Techniques Using Keithley SourceMeter Instruments with LabTracer Software
#2217 Trigger Synchronization of Multiple SourceMeter Instruments
#810 Optimizing Switch/Read Rates with Series 2000 DMMs and 7001/7002 Switch Systems
DC Electrical Characterization of RF Power Transistors
Quick Reference Guide to SCPI Commands
#2208 Solutions for Production Testing of Connectors
How to Choose and Apply Source Measure Unit SMU Instrume
#806 Production Testing of Thermistors Using the 2400 Digital SourceMeter
Eliminating Common SCPI Errors
  • 가족친화우수기업
  • 청년친화 강소시업
사업자등록번호 : 220-86-72761대표이사 : 신동만대표전화 : 070-7872-0701팩스 : 02-2167-3801
(우)07299 서울특별시 영등포구 경인로 775 (문래동 3가, 에이스하이테크시티 3동 2층)