모델 | 설명 | Quote |
LR8511 | 15 채널형 입력 모듈 |
The LR8511 alone is not capable of making measurements. Wireless logging station Model LR8410-20 is necessary to measure. The main unit and input modules are not bundled with the Battery Pack Z1007. Thermocouples are not provided by HIOKI, and must be purchased from a separate vendor.
Countries and regions where Bluetooth®wireless operation is currently supported: Japan, U.S.A., Canada, EU, Norway, Switzerland, Turkey, Russia, Vietnam, India, Singapore, Thailand, Australia, New Zealand, Taiwan and Indonesia.
*Models LR8512 to LR8515 may only be used in countries in which they have been certified.
These products emit radio waves. Use of radio waves is subject to licensing requirements in certain countries. Use in countries or regions other than those listed above may constitute a violation of law, exposing the operator to legal penalties.
Bluetooth® is a trademark of Bluetooth SIG, Inc. and licensed for use by HIOKI E.E. CORPORATION.
주요 특징
■ 기본 사양
WIRELESS UNIVERSAL UNIT LR8511 | |
Supported model | Model LR8410-20 |
Control and communications | Between instrument and unit: Bluetooth® 2.1 + EDR, Communications range: 30 m (98.43 ft), Security: SSP |
Measurement parameters | [No. of channels] 15 analog channels; isolated scanning method input (4 terminals: push-button type)
[Voltage] ±10 mV to ±100 V, 1-5 V f.s., max. 500 nV resolution [Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K, J, T, or other), max. 0.01 ˚C resolution [Temperature: Pt 100, JPt 100 sensor] -200 ˚C to 800 ˚C, max. 0.01 ˚C resolution (not isolated between channels) [Resistance] 0 Ω to 200 Ω f.s., max. 0.5 mΩ resolution (not isolated between channels) [Humidity] 5.0 to 95.0 % rh (use with optional sensor), 0.1 % rh resolution (not isolated between channels) [Max. rated voltage between isolated input channels] 300 V DC [Max. allowable input] ±100 V DC [Max. rated voltage from isolated terminals to ground] 300 V AC, DC |
Operating temperature | -20 °C to +60 °C (-4 °F to 140 °F) |
Power supply | [AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 23 VA Max. (including AC adapter), 7 VA Max. (exclusive of AC adapter)
[Internal battery] Using the Battery Pack Z1007 (optional accessory), 24 hours of continuous use (at 100 ms recording interval, 23 ˚C reference data), 120 hours of continuous use (at 1 minute recording interval, 23 ˚C reference data), 0.6 VA Max. [External power] 10 to 28 V DC, 7 VA Max. |
Dimensions and mass | 150 mm (5.91 in) W × 90 mm (3.54 in) H × 56 mm (2.20 in) D, 320 g (11.3 oz) |
Accessories | Instruction manual ×1, AC adapter Z1008 (with supplied power cord) ×1, Bracket ×1, M3×4 mm screw ×2 |
■ Optional sensors
■ Power supply